| Issue Type | Priority | Summary | Component/s |
| New Feature | Critical | A scene should work between a selected interval | Web UI |
| New Feature | Critical | The web interface should auto resize | Web UI |
| New Feature | Major | (Customer issue) Add option to download saved backups | Web UI |
| New Feature | Major | Staggering Cards | Web UI |
| New Feature | Major | Add additional support for 3rd party cameras | Web UI |
| New Feature | Minor | Add option to add a pincode to all the door locks from the unit on the same time | Web UI |
| Epic | Critical | Optimize WEB UI Loading Time | Web UI |
| Epic | Major | Fixing the workflow, function and overall user experience of the transition to go from a wired camera to a wireless camera. | Web UI |
| Improvement | Blocker | Sprint 5 - Device Wizard (Select Camera Type) | Web UI |
| Improvement | Critical | add ability to register a watch on tags like house mode | LuupEngine |
| Improvement | Critical | Add notification for the variable sl_TamperAlarm | Web UI |
| Improvement | Major | Sercomm camera plugin: update the unit IP on camera every time the plugin starts | Plugins |
| Improvement | Major | Vera alerts plugin is not compatible with UI7 | Plugins |
| Improvement | Major | Add option to delete Luup code from Triggers > Scenes | Web UI |
| Improvement | Major | Change "Tech Support" with "Customer Care" | Web UI |
| Improvement | Major | (Customer issue) Add preset modes for cameras with PT on UI7 | Web UI |
| Improvement | Major | Add trigger based on instant energy usage | Web UI |
| Improvement | Major | Center cards and remove navigation if only 2 cards are present | Web UI |
| Improvement | Trivial | Buttons inconsistency for device settings | Web UI |
| Bug | Blocker | (Customer Issue) Danfoss radiator does not wake-up and update setpoint | Device Integration |
| Bug | Blocker | (Customer Issue) Can't modify wake-up interval for battery operated devices | LuupEngine |
| Bug | Blocker | Variable "Mode" set to random values (>4) when changing house modes (Random) | LuupEngine |
| Bug | Blocker | (Customer Issue) ZWave Associations are not set at the inclusion time | LuupEngine |
| Bug | Blocker | Cannot delete saved snapshots | Web UI |
| Bug | Blocker | Cannot see recorded snapshots | Web UI |
| Bug | Blocker | List of countries - missing from Setup Wizard | Web UI |
| Bug | Blocker | 3G dongle information is not displayed on page | Web UI |
| Bug | Blocker | Unable to change setpoint temp on SRT321 (Hortmann Heater) by clicking on value | Web UI |
| Bug | Blocker | Account profile is not populated with the information from first setup | Web UI |
| Bug | Blocker | flash player issue on OEM - flash player not included in all oem override files | Web UI |
| Bug | Blocker | (Customer issue) A hidden device should NOT apear in House Modes | Web UI |
| Bug | Blocker | (Customer Issue) LuaUPnP crashes when multiple associations are set on a device | Web UI |
| Bug | Blocker | STG - Unable to update notifications limits | Web UI |
| Bug | Blocker | Unable to save changes on User Info page | Web UI |
| Bug | Critical | breach_delay value not considered when sensor goes to untrip before value expires | LuupEngine |
| Bug | Critical | Aeon Minimote [inv DZAMEu1] The 3rd and 4th buttons won't work when should trigger scenes or house mods | LuupEngine |
| Bug | Critical | (Customer Issue ) - EZMotion 3in1 by ExpressControls does not trip on motion | LuupEngine |
| Bug | Critical | Cannot set presets for Vistacam PT | Web UI |
| Bug | Critical | Device wizards -> use the translation function to process the text tokens | Web UI |
| Bug | Critical | Cannot play recorded video for camera Vistacam | Web UI |
| Bug | Critical | Basic user should not be allowed to secure/unsecure the unit | Web UI |
| Bug | Critical | All the devices has become generic devices. | Web UI |
| Bug | Critical | Not all devices displayed on Edit house modes | Web UI |
| Bug | Critical | Video records are not saved | Web UI |
| Bug | Major | /etc/cmh/persist is included in the backup | Bash Scripts |
| Bug | Major | (Customer Issue) Vision ZP3102 Motion and Temperature sensor does not untrip | Device Integration |
| Bug | Major | GetSessionKey doesn't discard trailing spaces in auth servers | LuupEngine |
| Bug | Major | Vera lite '+' button does not exit Include mode as expected on UI7 | LuupEngine |
| Bug | Major | CLONE - unit will not upgrade to ui7 with settings intact. | LuupEngine |
| Bug | Major | Jasco 45602 - not detected by the wizard | LuupEngine |
| Bug | Major | Jasco 45652 - not detected by the wizard | LuupEngine |
| Bug | Major | Not all files are removed after uninstall HP Streaming Agent | Plugins |
| Bug | Major | Change enable Customer care into Enable Tech support | Web UI |
| Bug | Major | Up and Down arrows are not working in "Control" tab - thermostats | Web UI |
| Bug | Major | "nobulk" check-box is displayed for all devices | Web UI |
| Bug | Major | "nobulk" check-box is displayed for all devices | Web UI |
| Bug | Major | Incorrect icon for binary light ( Category 3, subcategory 1) | Web UI |
| Bug | Major | Can't set ip on Philips Hue | Web UI |
| Bug | Major | Nyce Sensor images not showing in the add device wizzard | Web UI |
| Bug | Major | Unknown device appears in the Add device list | Web UI |
| Bug | Major | Restrict access to setpoint and hide current setpoint when thermostat is set to "OFF" | Web UI |
| Bug | Major | Block access to setpoint in Edit House Modes when you select "Off" for thermostats | Web UI |
| Bug | Major | Restrict access to "Firmware" menu for basic users | Web UI |
| Bug | Major | Basic user should be able to run scenes | Web UI |
| Bug | Major | Restrict access to "Insteon Settings" for basic users | Web UI |
| Bug | Major | Basic user can delete camera records | Web UI |
| Bug | Major | Countdown timer displayed for 1-2 seconds when changing to Home Mode - basic user | Web UI |
| Bug | Major | Retry button not working in Zigbee Devices | Web UI |
| Bug | Major | Status message displayed under control buttons for several devices on Scenes page | Web UI |
| Bug | Major | Status message displayed under control buttons for several devices | Web UI |
| Bug | Major | Scenes - Trigger of type Once should be validated at Save Scene | Web UI |
| Bug | Major | Incorrect icons for recorded videos/snapshots | Web UI |
| Bug | Major | Issue for Binary Lights (subcategory_num=2 and subcategory_num=1) | Web UI |
| Bug | Major | List of Video and Screenshots for camera has some bad icons | Web UI |
| Bug | Major | Variable 'paused' isn't set when a scene is edited | Web UI |
| Bug | Major | 'Next run' field doesn't show proper information | Web UI |
| Bug | Major | After reload scenes last run filed value is set to Never | Web UI |
| Bug | Major | When changing modes from Home to others timer will not be reset if change was canceled | Web UI |
| Bug | Major | Basic user permission to 'add favorites' | Web UI |
| Bug | Major | (FORUM REPORTED) Variables values are saved with the HTML escape codes in user_data | Web UI |
| Bug | Major | No confirmation message is displayed when snapshot or video captured | Web UI |
| Bug | Major | When deleting a room assigned to a number of scene , the specific scenes also are deleted | Web UI |
| Bug | Major | Device is not updated on UI if "invisible" parameter is toggeled | Web UI |
| Bug | Major | Action Delay flow should be changed | Web UI |
| Bug | Major | Issue in Add Insteon Interface | Web UI |
| Bug | Major | "N/A" displayed in Step 3: Name Your Device for Aeon DSB29 | Web UI |
| Bug | Major | ( Customer issue ) Leviton_RZRCZ4 scene controller - tab for off scenes is disabled | Web UI |
| Bug | Major | 2 streams displayed for Sercomm 8026 | Web UI |
| Bug | Major | (FORUM REPORTED) mismatch with scene triggers after upgrade from UI5 | Web UI |
| Bug | Major | Legacy scene from UI5 is not displayed in Scenes but it appears on device "scenes" tab | Web UI |
| Bug | Major | "Automatic Device Detection" option still enabled after it is unchecked | Web UI |
| Bug | Major | Inconsistency for Horstmann Relay thermostat SSR303 in Edit house modes page | Web UI |
| Bug | Major | "On" and "Off" buttons for Garage Door Opener (instead of "Opened" and "Closed") | Web UI |
| Bug | Minor | Issues in message displayed when Vera 3 is set "through a wi-fi access point" | LuupEngine |
| Bug | Minor | Icons for Alert Actions are changing when you hover the mouse cursor over them - in "Legend" section | Web UI |
| Bug | Minor | Secure SRT 321 temperature field isn't editable | Web UI |
| Bug | Minor | Inconsistency in dashboard shortcuts Doorlock label for unlocked state | Web UI |
| Bug | Minor | Inconsistency in dashboard shortcuts Doorlock vs Lights | Web UI |
| Bug | Minor | Inconsistency when hover over Luup Event in scene creation | Web UI |
| Bug | Minor | Issues in "Tech Support" page | Web UI |
| Bug | Minor | Scene trigger event : Light Sensor brightness goes below 0 is saved | Web UI |
| Bug | Minor | Camera - Recorded - When you are not logged in, the login doesn't seem like a link (but it works clicking on it) | Web UI |
| Bug | Minor | You shouldn't be able to create a room using this character "`" (Grave accent) | Web UI |
| Bug | Minor | Improve error message displayed in "Notifications Limits" page | Web UI |
| Bug | Minor | Superposition in Camera Live for cameras that support PT (when window is resized) | Web UI |
| Bug | Minor | Issue in Cameras->Large (when window is resized) | Web UI |
| Bug | Minor | Superposition in Add Device Wizard - VistaCam 700 (when window is resized) | Web UI |
| Bug | Minor | Bad alignment in "Other users" section when window is resized | Web UI |
| Bug | Minor | Issues in section "Electricity Cost" | Web UI |
| Bug | Minor | Inconsistencies in "Account Info" section | Web UI |
| Bug | Minor | "amp;" displayed in tooltips | Web UI |
| Bug | Minor | Bad position for "Remove" button in "Scenes" when window is resized and scene is disabled | Web UI |
| Bug | Minor | Issue when adding/removing devices to/from Favorites | Web UI |
| Bug | Minor | Inconsistency in Add Device Wizard for VistaCam 700 (WPS) | Web UI |
| Bug | Minor | Inconsistency "BYPASSED"-"Disarmed" | Web UI |
| Bug | Minor | Inconsistency "disarmed" - "Armed" | Web UI |
| Bug | Minor | Inconsistency in notifications order for thermostats | Web UI |
| Bug | Minor | Error message popup format is shown as success ( 3G dongle) | Web UI |
| Bug | Minor | Duplicate trigger can be created in scenes without any Luup Code added | Web UI |
| Bug | Minor | Wrong image displayed in Add Device Wizard for Aeon ZW080-C15 | Web UI |
| Bug | Minor | Issue in pop-up message displayed for abbreviation of the state name (CMS) | Web UI |
| Bug | Minor | Incorrect icon for glass break in Scenes, Step2 | Web UI |
| Bug | Minor | VUI Polish. '| |' Button Label for Validate Email and SMS | Web UI |
| Bug | Minor | Missing controls from "Advanced Settings" for Radiator (Heater) | Web UI |
| Bug | Minor | Wintop iDoorContact is not displayed correctly in UI7 | Web UI |
| Bug | Trivial | Vista Cam Motion sensor not working | LuupEngine |
| Bug | Trivial | (Customer issue) 3) If you change a scene name it will clear the last run time | Web UI |
| Bug | Trivial | Login redirect to wrong portal 'homebeta.getvera.com' | Web UI |